The Bulgin® Gas Mixer iMixproVario-2-1-100-EAR is a high-capacity gas mixing system designed to produce accurate, adjustable mixtures of two gases for industrial welding, fabrication and process gas applications.
Manufactured by IBEDA Germany, the iMixproVario combines integrated equal-pressure regulation with a diffusion mixing system to deliver consistent gas mixtures across varying gas withdrawal conditions.
The EAR configuration incorporates pre-adjusted inlet and outlet pressure regulators, providing an integrated gas mixing solution that simplifies installation and reduces the need for separate external pressure regulation equipment.
Featuring an adjustable mixing range of 2–95% by volume, the system provides precise control over gas composition, with a nominal capacity class of 100 Nm³/h and actual flow performance dependent on operating pressures and gas mixture.
Key Features
Variable two-gas mixing with adjustable mixture composition
2–95% mixing range by volume, subject to gas combination and technical limits
EAR configuration with integrated inlet and outlet pressure regulators
High mixing accuracy in accordance with ISO 14175
Integrated equal-pressure regulation for consistent gas mixing
Diffusion mixing system for reliable mixture production
Designed to maintain mixture consistency during variations in gas withdrawal
Compensates for inlet pressure differences through integrated constant-pressure regulation
Automatic interruption of mixture production if a gas supply is interrupted
No additional buffer vessel required for discontinuous gas withdrawal
Integrated inlet filters to protect against contamination
No electrical power supply required for gas mixture production
Stainless steel housing with robust industrial construction
Low-maintenance design
Optional integrated gas analysis for process control
EAR – Integrated Inlet & Outlet Pressure Regulation
The EAR configuration is designed to provide a more integrated gas mixing solution by incorporating pre-adjusted inlet and outlet pressure regulators within the mixer assembly.
These regulators control the incoming gas supply conditions and mixed gas outlet pressure, reducing the need for separately installed pressure regulation equipment.
Key Advantages
Integrated inlet pressure regulation
Integrated mixed gas outlet pressure regulation
Simplified gas supply installation
Reduced requirement for external pressure regulators
Consistent operating conditions for gas mixture production
Compact, integrated equipment configuration
This makes the iMixproVario-2-1-100-EAR particularly suitable for industrial installations requiring controlled gas mixing and pressure regulation within a single system.
Precision Gas Mixing
The iMixproVario uses a diffusion mixing system with integrated equal-pressure regulation to produce controlled mixtures of two compatible gases.
The individual gas supplies are regulated to maintain consistent mixing conditions, reducing the influence of differences in inlet pressure.
This configuration supports accurate mixture production even when downstream gas consumption varies.
The mixing ratio can be individually adjusted within the technical limits of the selected gas combination.
Mixing Accuracy
| Additive Gas Concentration | Mixing Precision |
|---|
| 1–5% by Volume | ±0.5% Absolute |
| Greater than 5–20% by Volume | ±10% of Nominal Value |
| Greater than 20% by Volume | ±2% Absolute |
These accuracy specifications apply within the manufacturer's stated operating conditions.
Compatible Gas Combinations
The iMixproVario is available in configurations for mixing selected industrial and process gases.
| Carrier Gas | Compatible Additive Gases |
|---|
| Argon (Ar) | Carbon Dioxide (CO2), Helium (He), Nitrogen (N2), Oxygen (O2), Hydrogen (H2) |
| Nitrogen (N2) | Carbon Dioxide (CO2), Helium (He), Oxygen (O2), Hydrogen (H2) |
| Carbon Dioxide (CO2) | Oxygen (O2) |
The appropriate mixer configuration must be selected according to the required gas combination, mixture composition and application.
High-Capacity Gas Mixing Performance
The iMixproVario-2-1-100-EAR belongs to the manufacturer's 100 Nm³/h capacity class, with infinitely variable gas withdrawal within the applicable operating range.
The manufacturer's flow data demonstrates that actual capacity depends on inlet pressure, outlet pressure and gas composition.
Flow Performance – 100 Nm³/h Model
| Inlet Pressure | Outlet Pressure | Published Flow Capacity |
|---|
| 10 bar | 0.5 bar | 126 Nm³/h |
| 10 bar | 2 bar | 120 Nm³/h |
| 10 bar | 4 bar | 114 Nm³/h |
| 10 bar | 5 bar | 100 Nm³/h |
| 8 bar | 0.5 bar | 100 Nm³/h |
| 8 bar | 2 bar | 93 Nm³/h |
| 6 bar | 2 bar | 60 Nm³/h |
Flow capacities are based on nitrogen-reference conditions. Gas-specific correction factors apply.
Maximum published nitrogen-reference flow capacity: 126 Nm³/h at 10 bar inlet pressure and 0.5 bar outlet pressure.
The appropriate operating conditions should be established according to the required gas composition, delivery pressure and maximum downstream gas consumption.
Integrated Gas Analysis – Optional
The iMixproVario can be supplied with optional integrated gas analysis for additional process control.
This option provides gas mixture monitoring for applications where verification of the produced gas composition is required.
The availability and configuration of integrated gas analysis should be confirmed when specifying the mixer.
Typical Applications
MIG/MAG welding shielding gas mixtures
Industrial fabrication and manufacturing
Centralised welding gas distribution systems
Modified atmosphere packaging (MAP) gas supply
Food processing and packaging applications
Industrial process gas mixing
Laboratory and testing applications
Specialty gas supply systems
Applications requiring adjustable two-gas mixtures
Technical Specifications
| Specification | Value |
|---|
| Product Type | Variable Two-Gas Mixer |
| Brand | Bulgin® Gas Equipment |
| Manufacturer | IBEDA Germany |
| Model | iMixproVario-2-1-100-EAR |
| Number of Gases | 2 |
| Mixing Technology | Diffusion Mixing System |
| Pressure Regulation | Integrated Equal-Pressure Regulation |
| EAR Configuration | Integrated Pre-Adjusted Inlet & Outlet Pressure Regulators |
| Mixing Range | 2–95% by Volume |
| Nominal Capacity Class | 100 Nm³/h |
| Maximum Published Flow Capacity | 126 Nm³/h* |
| Minimum Inlet Pressure | 400 kPa (4 bar) |
| Maximum Inlet Pressure | 1,000 kPa (10 bar) |
| Outlet Pressure Range | 50–800 kPa (0.5–8 bar), Depending on Inlet Pressure |
| Gas Inlet Connection | G1/2 RH Female |
| Mixed Gas Outlet Connection | G3/4 RH Female |
| Housing Material | Stainless Steel |
| Internal Materials | Brass, Stainless Steel, Elastomer, Copper & Anodised Aluminium |
| Operating Temperature | −10°C to +50°C |
| Electrical Supply | Not Required for Gas Mixture Production |
| Integrated Gas Analysis | Optional |
| Height | 500mm |
| Width | 500mm |
| Depth | 210mm |
| Weight | Approximately 18–38 kg (Range Dependent) |
| Pressure Equipment Compliance | CE Marking – Pressure Equipment Directive 2014/68/EU |
Maximum published flow capacity is based on nitrogen-reference conditions at 10 bar inlet pressure and 0.5 bar outlet pressure. Actual capacity varies with gas composition and operating pressures.
Designed for High-Capacity Gas Mixing Applications
The Bulgin® Gas Mixer iMixproVario-2-1-100-EAR combines adjustable gas mixture control, integrated pressure regulation and diffusion mixing technology in a robust industrial system.
With integrated inlet and outlet pressure regulators, adjustable two-gas mixing and published nitrogen-reference flow capacities up to 126 Nm³/h, the system provides a practical solution for demanding industrial gas distribution applications.
Its stainless steel housing, integrated pressure regulation and low-maintenance design make it suitable for professional installations requiring consistent gas mixture production.
Note: Gas compatibility, mixing range, accuracy and available flow capacity depend on the selected configuration and operating conditions. Confirm the required gas composition, inlet and outlet pressures, maximum gas consumption and connection requirements before specifying the equipment. Suitability for food-grade gas applications must be confirmed for the selected configuration. Gas mixers must be leak-tested at least once per month and may only be opened or repaired by the manufacturer.